Eiconcard C Series

Eiconcard C Series Boards

Overview

The Eiconcard C Series are intelligent multi-protocol traditional wide-area network (WAN) interface boards for PCI / PCIe based workstations. The C Series of synchronous serial interface adapters are targeted for X.25, HDLC,PPP or SNA/SDLC implementations.  The Eiconcard C Series offers connectivity through V.24 and/or ISDN ports, supporting line speeds of up to 64 Kbps and 128 Kbps respectively.

The Eiconcard C Series allows you to connect over a variety of traditional WAN protocols such as X.25, Frame Relay, PPP, SDLC and HDLC, over leased lines, dial-up lines or ISDN lines. The Eiconcard C Series offloads the server from low level protocol processing tasks, resulting in a saving of server CPU resources.

The Eiconcard C Series works in conjunction with Dialogic software, and is supported by Dialogic development tools and third-party products. The Eiconcard C Series offers a comprehensive warranty of 5 years.

Key Features

Multi-protocol

Worlwide certification

World class protocol interoperability

On-board CPU

V.24 and ISDN port

PCI or PCIe low profile

Resource Links

Specifications

Hardware - C91
  • Motorola 68302 microprocessor @ 15.36 MHz
  • 512KB FLASH & 512KB DRAM
  • Bus Type: PCI 2.1 32bit / 33MHz (5V)
  • Plug and Play
  • One V.24 connector
  • One ISDN S/T interface
Supported Operating Systems
  • Windows 2000
  • Windows XP, Server 2003, Windows 7, Server 2008 and 2008R2
  • Linux - Redhat Enterprise Linux and SUSE Linux Enterprise Server
Serial Interface
  • Autodetect cable interface
  • V.24 DB-25 · CCITT V.24 Signaling
  • CCITT V.28 Electrical
  • CCITT X.21bis Electrical and signaling
  • EIA RS-232-C Electrical and signaling
Warranty
  • 5 year warranty
Environmental Requirements
  • Operating temperature: 0°C to +50°C
  • Operating humidity: 5% to 90% (non-condensing)
  • Barometric operating pressure: 86 to 106 kPascals
  • Maximum tolerance in power supply variation: +5% to -5%
  • Storage temperature: -20°C to +70°C
Certifications
  • European Council Directive 73/23/EEC and 89/336/EEC
  • European Radio and Telecommunications Terminal Equipment (R&TTE) Directive 1999/5/EC.
  • EN 60950:2000
  • EN 55022:1998
  • EN 55024:1998 including: EN 61000-4-2:1995, EN 61000-4-3:1996, EN 61000-4-4:1995, EN 61000-4-5:1995, EN 61000-4-6:1996 and EN 61000-4-11:1994.span>
  • TIA-968 (FCC Part 68)
  • FCC Part 15 Class B
  • Industry Canada CS03 Issue 8
  • Industry Canada ICES-003 (covered per FCC part 15)
  • AS/NZS 3548 – Australia EMI (covered per EN 55022)
  • AS/NZS 60950 – Australia safety
  • TS031? Australia requirements for ISDN basic access
Technical Specification
Hardware C91 V2
  • MCP850 protocol processor
  • 512KB RAM
  • Bus Type: PCI 2.2 32bit / 66MHz (3V PCI-X compatible)
  • Plug and Play
  • One V.24 connector
  • One ISDN S/T interface
Supported Operating Systems
  • Windows 2000
  • Windows XP, Server 2003, Windows 7, Server 2008 and 2008R2
  • Linux - Redhat Enterprise Linux and SUSE Linux Enterprise Server
Software Features
  • Automatic hardware detection
  • Remote management with SNMP
  • Winsock X.25 Support
  • X3 PAD Support
  • WAN Mini-port Driver for PPP over X25
  • Microsoft Host Integration Server
  • LAN Emulation driver for IP over X.25
  • Support Microsoft Exchange Server
Serial Interface
  • V.24 DB-25 · CCITT V.24 Signaling
  • CCITT V.28 Electrical
  • CCITT X.21bis Electrical and signaling
  • EIA RS-232-C Electrical and signaling
Warranty
  • 5 year Warranty
Environmental Requirements
  • Operating temperature: 0°C to +60°C
  • Operating humidity: 5% to 90% (non-condensing)
  • Barometric operating pressure: 86 to 106 kPascals
  • Maximum tolerance in power supply variation: +5% to -5%
  • Storage temperature: -40°C to +70°C
Certifications
  • EN 60950:2000
    Safety Information Technology, including electrical business equipment
  • EN 55022:1998 Class B: Information technology equipment –Radio disturbance characteristics- Limits and methods of measurement
  • EN 55024: 1998 Information Technology Equipment – Immunity characteristics – Limits and methods of measurements including EN 61000-4-2:1995, EN 61000-4-3:1995, EN 61000-4-4:1995, EN 61000-4-5:1995, EN 61000-4-6:1996 , EN 61000-4-8:1993 and EN 61000-4-11:1994.
  • Council Directive 73/23/EEC and 89/336/EEC
  • The Radio and Telecommunications Terminal Equipment (R&TTE) Directive 1999/5/EC (CE Mark)
  • FCC Part 68
  • FCC Part 15 Class B
  • Industry Canada CS03 Issue 8
  • Canadian interference equipment regulations. Limits and methods of measurements of radio interference characteristics of information technology equipment ICES-003
  • Australia safety standard
  • Australia/New Zealand Standard AS/NZS 3548( covered per EN55022), AS/NZS 60950 plus TS031
Dimensions
  • 4.2" x 5.9"

Documents

Find related manuals, data sheets, whitepapers, case studies and more. Click the icon to expand.

Ordering Information

Use the Purchase page linked below to find partners to purchase Dialogic products. The order codes below are for your reference when making a purchase.

Where to Buy
ProductOrder CodeDescription

Eiconcard C91 V2

306-231

PCI, Ports: V.24 WAN and ISDN S/T

Eiconcard C91 PCIe

306-406

PCIe,Low Profile, Ports: V.24 WAN and ISDN S/T, optional full height bracket

Cable (C91 V2)

300-007

V.24 DCE cable

Cable (C91 V2)

300-022

V.24 null-modem cable

Cable (C91 V2)

300-048

V.24 null-modem cable (gender-changed)

Cable (C91 PCIe)

300-402

V.24 DCE cable (Micro-D 25 to DB 25)

Cable (C91 PCIe)

300-401

V.24 null-modem cable (Micro-D 25 to DB 25)

Web Analytics