You are here: CSP API Reference > 7 Timers and Filters > E1 Timers
The table below shows the timers used with the E1 component (0x01).
|
Timer ID |
Description: (State Used); Timer Description |
Default Value (10 ms) |
|---|---|---|
|
1 |
(S19) Incoming Layer 4 busy out Acknowledge wait |
400 |
|
2 |
(S2) Incoming Stage 1 FWD digit receive wait |
2000 |
|
3 |
(S3) Incoming Stage 2 FWD digit receive wait |
2000 |
|
4 |
(S4) Incoming Stage 3 FWD digit receive wait |
2000 |
|
5 |
(S5) Incoming Stage 4 FWD digit receive wait |
2000 |
|
6 |
(S13) Layer 4 Connect wait |
24,000 |
|
7 |
(S14) Layer 4 wait |
400 |
|
8 |
(S21) Clear Forward (idle line signaling) wait |
1500 |
|
9 |
(S3) Incoming Stage 2 Initial FWD digit receive wait |
2000 |
|
10 |
(S2) Incoming Stage 1 Initial FWD digit receive wait |
2000 |
|
11 |
(S5) Incoming Stage 4 Initial FWD digit receive wait |
2000 |
|
12 |
(S4) Incoming Stage 3 Initial FWD digit receive wait |
2000 |
|
13 |
(S15) Layer 3 Circuit Release wait |
10 |
|
14 |
(S18) Layer 3 Circuit Release wait |
10 |
|
15 |
(S6) Host Control Wait |
6000 |
|
16 |
(S13) Layer 3 Connect wait |
24000 |
|
17 |
(S29) Seize Acknowledge wait |
400 |
|
18 |
(S31) Time to wait before transmitting idle signal after detecting glare |
10 |
|
19 |
(S32) Time to wait before looking for idle signal after transmitting idle signal after detecting glare |
10 |
|
20 |
(S39) Outgoing Stage 1 BWD R2 signal wait |
1500 |
|
21 |
(S39) Outgoing Stage 1 Initial BWD R2 signal wait |
1500 |
|
22 |
(S41) Outgoing Stage 2 BWD R2 signal wait |
1500 |
|
23 |
(S41) Outgoing Stage 2 Initial BWD R2 signal wait |
1500 |
|
24 |
(S43) Outgoing Stage 3 BWD R2 signal wait |
1500 |
|
25 |
(S43) Outgoing Stage 3 Initial BWD R2 signal wait |
1500 |
|
26 |
(S45) Outgoing Stage 4 BWD R2 signal wait |
1500 |
|
27 |
(S45) Outgoing Stage 4 Initial BWD R2 signal wait |
1500 |
|
28 |
(S46) Outgoing wait for answer |
24000 |
|
29 |
(S48) Outgoing Layer 4 Clear wait |
400 |
|
30 |
(S49) Outgoing idle line signal wait |
12000 |
|
31 |
(S50) Outgoing idle line signal wait after glare detected |
12000 |
|
32 |
(S24) Host Control wait |
24000 |
|
33 |
(S33) Time to wait for Clear Forward after glare detected |
1000 |
|
34 |
Receive line signaling filter |
4 |
|
36 |
(S6, S24) Incoming BWD R2 Cycle Complete Event wait |
400 |
|
38 |
(S10) Time to wait for idle line signaling after invalid line signal detected while receiving FWD R2 digits |
2000 |
|
39 |
(S22) Layer 3 Clear Forward wait |
300 |
|
40 |
(S39) Outgoing Stage 1 BWD A signal wait after sending all of Stage 1 FWD digits |
2000 |
|
41 |
(S2, S3, S4, S5) FWD R2 digits receive wait when String Collection Data field in Inpulsing Parameters Configure is set to 0xFF |
144 |
|
43 |
R2 Cycle Complete Event wait |
200 |
|
44 |
Used in conjunction with the following two ICBs: Do Call Progress Analysis (0x09) Do Call Progress Analysis Without Line Signaling (0x10) When these instructions are processed, a message is sent to TC to do CPA and this timer is started. If no response is received from TC within this time, the channel is purged with reason 138 (0x8A) - Failure to Receive Call Progress Analysis Result. |
1500 |
|
45 |
(S43) Time to wait for next BWD R2 signal when stage 3 digits have been outpulsed |
2000 |