Outseize Instruction

Topic Location: ClientView Pane Reference

Description:

Use this pane to form a list of configuration instructions. Once pane is created there is a drop down menu in the Instruction Type field. The Instruction Type Field will allow the user to create several of these messages to form a list of instructions for Outseize control on CAS channels. Within ClientView you must create a separate Outseize Instruction entry for each instruction that you add to the list. Once list is created you can assign the Variant to a specific Channel Group. The IMG uses the list created to perform an Outseize on channels in a Channel Group.

 

Important Note: The order in which the instructions appear in the ClientView tree is the order in which they will be sent.

Accessing this Pane

Dialogic IMG EMS -> Signaling -> <Variant Name> -> Outseize Instruction

Maximum Objects:

19 per Signaling Variant

Related Topics:

Configuring CAS

Previous Configuration Required

Signaling Variant

 

ClientView Pane (T1):

 

 

Field Descriptions (T1):

Instruction Type:

 

Outseize Instruction Type

Instructs Switch To:

Scan for Wink N

Scan for Wink N using the appropriate wink parameters. Scan a specific Wink like Wink 3 etc.

Report Call Processing Event

Report the completion of the previous instruction along with any associated data. This instruction typically follows a Scan for Wink or Scan for Off-Hook instruction.

Outpulse Stage N address info

Outpulse a given stage of digits. You can first Outpulse stage: 1 string: 1 and then stage: 2 string; 2.

Send Host Acknowledgement

Send the host a positive ACK to an Outseize Control message if all previous instructions have been successfully carried out. If a previous instruction is not successful, the list aborts at that point and the host is sent a negative ACK. If this instruction is sent, include only one per message and it should be the last instruction before Wait For Host Control.

Delay N Milliseconds

Use this inseize instruction to enter a delay between two Inseize Instructions

 

Second Field: (Wink Number, Event, Stage Number) The second field changes as different Instruction Types are selected. Below is table showing this.

 

Outseize Instruction Type

Second Field: (Wink #, Event, Stage Number)

Data

Scan for Wink

Wink Number

Wink 1 — Wink 8

Report Call Processing Event

Event

· Off Hook

· Wink 1 — Wink 8

· DialTone Detected

· Backward R2

· First Digit Detected

Outpulse Stage N address info

Stage Number

· Stage 1

· Stage 2

· Stage 3

· Stage 4

Send Host Acknowledgement

DATA

NO DATA

Delay N Milliseconds

DATA

NO DATA

 

 

 

 

 

Delay Time (ms) (T1 Only):

Applies to Instruction Type of 'Delay n Milliseconds'. Use this Inseize instruction to enter a delay between two Outseize Instructions. Use the slider or enter a value in the Value: box

 

 

 

 

 

 

ClientView Pane (E1)

 

Field Descriptions: (E1)

Instruction Type:

 

Outseize Instruction Type

Instructs Switch To:

Scan for Wink N

Scan for Wink N using the appropriate wink parameters. Scan a specific Wink like Wink 3 etc.

Report Call Processing Event

Report the completion of the previous instruction along with any associated data. This instruction typically follows a Scan for Wink or Scan for Off-Hook instruction.

Outpulse Stage N address info

Outpulse a given stage of digits. You can first Outpulse stage: 1 string: 1 and then stage: 2 string; 2.

Send Host Acknowledgement

Send the host a positive ACK to an Outseize Control message if all previous instructions have been successfully carried out. If a previous instruction is not successful, the list aborts at that point and the host is sent a negative ACK. If this instruction is sent, include only one per message and it should be the last instruction before Wait For Host Control.

Cancel R2 Receiver

Release a DSP MFR2 Tone Receiver.

Scan for backward R2 signal

Scan for an MFR2 backward signal.

 

 

Second Field: (Wink Number, Event, Stage Number) The second field changes as different Instruction Types are selected. Below is table showing this.

 

Outseize Instruction Type

Second Field: (Wink #, Event, Stage Number)

DATA

Scan for Wink N

Wink Number

Wink 1 — Wink 8

Report Call Processing Event

Event

· Off Hook

· Dial Tone Detected

· Backward R2

· First Digit Detected

Send Host Acknowledgement

DATA

NO DATA

Cancel R2 Receiver

DATA

NO DATA

Scan for backward R2 signal

DATA

NO DATA

 

Delay Time (ms):