SS7 Link

Topic Location: ClientView Pane Reference

Description:

This object identifies an SS7 link within an SS7 link set to an APC.

Accessing this Pane:

Dialogic IMG EMS -> Logical IMG -> Physical IMG -> SS7  -> SS7 Stack -> SS Link Set -> SS7 link

Maximum Objects:

IMG 1010 = 64 per Logical IMG

IMG 1004 = 4 per Remote Node

Related Topics:

Configuring_SS7_Signaling_Links

 

Click on the Technical Notes link for more information on SS7 Links.

 

When configuring a SS7 Link, the following happens:

An SS7 link is assigned on a specific channel/offset. The link will go into the alignment procedure trying to align and come in service.

ClientView Pane 10.3.x - 10.5.0

 

ClientView Pane 10.5.1

 

Field Descriptions:

Primary/Secondary (10.3.x - 10.5.0):

This field specifies whether the SS7 link is supported by the primary or secondary physical IMG.

 

Link ID:

This field specifies the SS7 link ID. Link ID 0 – 63 are allowed for the primary physical IMG, while link ID 64 – 127 are allowed for the secondary physical IMG.

 

IMG (10.5.1+):

This field has a drop down menu with all IMG's configured. Select the Physical IMG that the link being created will be associated with.

 

Interface - Offset:

This field specifies the physical offset (span) on which the SS7 link will be configured.

 

Channel:

This field specifies the channel from the physical offset (span) chosen in the previous field on which the SS7 link will be configured.

 

Signaling Link Code:

This field specifies the SLC of the SS7 link. SLC is unique across any SS7 link set with a range of values of 0 – 15.

 

Data Rate:

This field specifies the data rate of the SS7 signaling link.

NOTE: For T1 SS7 links with line coding configured for B7ZS, only the 48 Kbps data rates are valid.

 

Electrical Interface:

DS1 Channel

DS1 Channel Data

 

Monitoring Fields:

Link Status:

This monitoring field displays the status of the SS7 link whether it is in or out of service.

 

Buttons

In Service:

This buttons brings the SS7 link in service.

Out Of Service:

This buttons takes the SS7 link out of service.

Inhibit:

This buttons inhibits the SS7 link.

UnInhibit:

This buttons uninhibits the SS7 link.

 

 

Display Table: