Scenario 1 - One Subnet

In this scenario all traffic runs over one subnet. Do not configure the CPU Physical Interface for Redundant Control. It is configured automatically during the BootP process. When configuring H.323 or SIP Signaling, select 10.10.25.2 for the IP Address in the H.323 Signaling or SIP Signaling pane.

 

Stream Type and Where Assigned

Sample IP Address

Physical Interface

Logical Interface

Port on Back Plane

Control and Signaling

Assigned at BootP not Pane

10.10.25.2

CPU/CPU H.323/SIP

Redundant Control

CTRL 0 or 1

IP Bearer Data

Assign in Network Interface Pane

10.10.25.100

VoIP Module 0

Redundant Data

DATA 0 or 1

IP Bearer Data

Assign in Network Interface Pane

10.10.25.101

VoIP Module 1

Redundant Data

DATA 0 or 1

 

dg_1_subnet.png

 

 

ClientView Panes:

 

sc_ni_h323.png

 

sc_ni_voip0.png

 