Scenario 1 - One Subnet IMG 1004

In this scenario all traffic runs over one subnet. The IP address of the interface labeled Ctrl> is configured automatically during the BootP process. When configuring H.323 or SIP Signaling, select 10.10.25.2 for the IP Address in the H.323 Signaling or SIP Signaling pane.

 

dg_1_subnet_1004.png

Stream Type and Where Assigned

Sample IP Address Physical Interface Logical Interface Port on Back Plane
Control: Assigned at BootP 10.10.25.2 CPU/CPU H.323/SIP CTRL CTRL
Data: Assigned in Network Interface Pane 10.10.25.100 VoIP Module 0 Data Data

 

 

ClientView Panes

sc_ni_h323.png

 