Scenario 3 - Two Subnets B: Data/Signaling and Control

In the following scenario, combine the signaling and data on one subnet and the control on another subnet. When configuring H.323 or SIP Signaling, select 10.10.30.70 for the IP Address in the H.323 Signaling or SIP Signaling pane.

 

Stream Type and Where Assigned

Sample IP Address

Physical Interface

Logical Interface

Port on Back Plane

Control

Assigned at BootP

10.10.25.2

CPU

Redundant Control

CTRL 0 or 1

H.323 or SIP Signaling

Assigned at Network Interfaces Pane

10.10.30.70

CPU (H.323/SIP)

Redundant Data

DATA 0 or 1

IP Bearer Data

Assigned at Network Interfaces Pane

10.10.30.100

VoIP Module 0

Redundant Data

DATA 1 or 0

IP Bearer Data

Assigned at Network Interfaces Pane

10.10.30.101

VoIP Module 1

Redundant Data

DATA 1 or 0

 

dg_2_subnets2.png

 

ClientView Panes:

 

sc_ni_2_subnetscpu.png

 

sc_ni_2_subnetsh323.png

 

sc_ni_2_subnetsvoip0.png

 

sc_ni_2_subnetsvoip1.png