System requirements

To install and use CX 2000C boards, your system must have:

Note: The CX 2000C board will power up and function only in a chassis with a telephony backplane.

Caution:

Each CX board is shipped in a protective anti-static container. Leave the board in its original container until you are ready to install it. Handle the board carefully and hold it only by its handles. We recommend that you wear an anti-static wrist strap connected to a good earth ground whenever you handle the board.

Selecting a CompactPCI chassis

Use the following guidelines when choosing a CompactPCI chassis:

If an air flow rating is not specified, use one fan with a rating of at least 50 cubic feet per minute (CFM) for every four CX 2000C boards. There should be no preheating of the air before cooling the CX 2000C board.

Chassis connection

Chassis backplane current per board

-V bat

1A

V bat Rtn

1A

SELVbat

1A

SELVbatRtn

1A

VRG

0.250A

VRGRtn

0.250A

NMS supplies a cable to connect a power supply to a chassis with a telecom power bus. One end of the cable has spade lugs to connect to the chassis. To learn more about connecting power in this way, refer to Using the NMS rack mount power supply chassis.

The following table shows the pins requiring clearance for J3/P3:

Pos#

RowZ

RowA

RowB

RowC

RowD

RowE

RowF

19

 

 

 

 

 

 

 

18

 

 

T33

 

 

 

 

17

 

 

R33

T39

T44

 

 

16

 

 

T34

R39

R44

 

 

15

 

 

R34

T40

T45

 

 

14

 

 

T35

R40

R45

 

 

13

 

 

R35

T41

T46

 

 

12

 

 

T36

R41

R46

 

 

11

 

 

R36

T42

T47

 

 

10

 

 

T37

R42

R47

 

 

9

 

 

R37

T43

T48

 

 

8

 

 

T38

R43

R48

 

 

7

 

 

R38

 

 

 

 

6

 

 

 

 

 

 

 

5

 

 

 

 

 

 

 

4

 

 

 

 

RING2

 

 

3

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

1