Using the NMS rack mount power supply chassis

To supply talk battery power to the station telephones and to power ringing (if necessary), an external power supply is required.

NMS supplies a rack mount power supply chassis that can contain up to four interchangeable supply modules. Each module can power up to two CX 2000 boards. Four modules produce a total combined output of 8.8A for -48 V and -30V/-24 V. The ring output total is 0.68A. The supply outputs are isolated from ground and rely on the CX 2000 board to ground the return line. This provides the best EMI performance. The following illustration shows a rack mount power supply chassis with four modules:

The power supply autoranges for global power standards and can be configured for local ring frequency standards to satisfy global deployment requirements.

Normal configuration

The following table indicates the required number of power supply chassis and modules based upon the number of CX 2000 boards in your system. The table assumes a normal configuration, in which all stations are active on each board. Sufficient ring signal is supplied so that for short (not continuous) peak demand periods, more than 20 telephones rated at 1.0 REN can ring simultaneously.

Number of CX boards

Power supply chassis required

(Each chassis includes one power supply module)

Expansion modules required

1

1

0

2

1

0

3

1

1

4

1

1

5

1

2

6

1

2

7

1

3

8

1

3


Redundant power supply configuration

To provide redundancy, or to supply additional ring power to your system, install one more power supply module then you need. The module-to-board connectors on all modules are wired in parallel, so if one module fails, another module supplies power to the first module's board connector. This helps ensure uninterrupted power to any connected boards in the unlikely event that a module fails.

If you connect the power supply to a UPS, the contribution of a fully populated power supply chassis is 1.8 kW.

The following table indicates the required number of power supply chassis and modules in a configuration in which an extra power supply module is installed:

Number of CX boards

Power supply chassis required

(Each chassis includes one power supply module)

Expansion modules required

1

1

1

2

1

1

3

1

2

4

1

2

5

1

3

6

1

3

7

N/A

N/A

8

N/A

N/A


In a system containing seven or eight CX boards, there is a maximum of four modules per chassis.

Rack mount considerations

Consider the following items when installing a power supply in a rack:

Note: In the unlikely event that the power supply current exceeds the current rating, the power supply output clamps to zero to protect the supply. The power supply may need to be turned off momentarily and then turned back on to restore normal operation.

Connecting the NMS power supply

You can connect power supply modules directly to CX 2000 boards.

NMS supplies two cables for these connections:

Connecting directly to boards

To connect the NMS power supply directly to each board:

  1. On the power supply chassis, set the VOLTAGE switch to 24 V.

  2. On the power supply, set the FREQUENCY switch to a ringing frequency (default = 20 Hz).

The default ringing frequency setting (20 Hz) operates correctly for most applications. However, you can change this setting if a station does not ring when directed, or to change the sound of the ringer to match that of other devices in the target country or region.

Warning:

Do not change the frequency or voltage while the power supply is operating.


  1. Plug the Y end of the cable into the TELCO POWER connectors on the CX 2000 boards.

  2. Plug the other end of the cable into the power supply.

  3. When you have finished configuring the power supply, plug it into a power source.

Alarm signal connector

The NMS rack mount power supply has a DB9 connector on the rear panel that can be used to indicate an alarm condition. The following table lists the pinouts of this connector:

Pin

Description

1

Chassis ground

2

1.5K resistor to +12 V DC

3

4.7K resistor to +5 V DC

4

Alarm signal output. This is an open collector NPN transistor with the emitter connected to COMMON. The transistor is normally on. It is turned off for an alarm condition. The transistor is rated for 20 V DC and 5 mA. The 4.7K resistor on pin 3 or pin 7 can provide pull-up to +5 V DC.

5

Optional signal

6

+5 V DC @ 3 mA

7

4.7K resistor to +5 V DC

8

COMMON

9

COMMON


Powering up the power supply

To power up the supply, turn on the POWER ON switch located on the rear panel of the unit. When the unit is operating properly, the green POWER ON indicator on the front panel glows. In addition, the POWER ON indicator on each module glows (visible on the rear panel of the unit).