Error type 9a00

The following table lists the 9a00 type (HMIC) errors:

Error code

Error name

Description

Category

-9

 

Refer to AG clock manager errors.

 

-3072

HMICERR_LIBRARY_NOT_USABLE

Not used.

3

-3073

HMICERR_LIBRARY_NOT_INITIALIZED

Not used.

3

-3074

HMICERR_LOCK_CREATION_FAILED

Could not create AMX resource semaphore for HMIC.

3

-3075

HMICERR_LOCK_FAILED

Could not lock HMIC resource semaphore.

3

-3076

HMICERR_UNLOCK_FAILED

Failed to unlock HMIC resource semaphore.

3

-3077

HMICERR_DELAY_FAILED

Frame delay failed.

3

-3078

HMICERR_CONNECT_REFERENCE_CNT

Not used.

3

-3079

HMICERR_INVALID_BUS

Bus is invalid.

3

-3080

HMICERR_INVALID_STREAM

Stream is invalid.

3

-3081

HMICERR_INVALID_TIMESLOT

Timeslot is invalid.

3

-3082

HMICERR_INVALID_CLOCK_PARM

Not used.

3

-3083

HMICERR_INVALID_MODE

Framed connect mode is invalid if MVIP is in connect mode, and vice versa.

3

-3084

HMICERR_INVALID_PARAMETER

Physical address received as source while breaking connection.

3

-3085

HMICERR_NO_PATH

Failed to make a connection to DSP driver.

3

-3086

HMICERR_SWICH_VERIFY_FAILED

Switch number passed from the DSP driver is greater than number of secondary HMICs.

3

-3087

HMICERR_CONNECT_NOT_SUPPORTED

This error is returned if one of the following was true while making or breaking a mapping:

  • Physical address is already mapped to a logical address.

  • Mapping from one secondary HMIC to another.

  • Mapping logical to logical.

3

-3088

HMICERR_MODE_NOT_SUPPORTED

HSEC8K_DRIVEN_BY_OSC mode for configuring sec8k clock is not supported.

3

-3089

HMICERR_MVIP_NOT_ENABLED

Failed to configure HMIC clock because MVIP is not enabled.

3

-3090

HMICERR_INVALID_MAP

Not used.

3

-3091

HMICERR_LOCAL_NOT_ENABLED

Local is not enabled. Informational message.

3

-3092

HMICERR_HW_INTERFACE_FAIL

Unknown mode (not framed connect or connect).

3

-3093

HMICERR_CONSUME_MESSAGE

Not used.

3

-3110

HMICERR_NO_RESOURCE

No free entries in HMIC mapping database.

3

-3111

HMICERR_INVALID_CLK_MAIN_SRC

Invalid clock source.

3

-3112

HMICERR_INVALID_CLK_FBK_SRC

Invalid fallback source.

3

-3113

HMICERR_INVALID_CLK_NTREF1_SRC

Invalid NETREF1 source.

3

-3114

HMICERR_INVALID_CLK_NTREF2_SRC

Invalid NETREF2 source.

3

-3115

HMICERR_INVALID_CLK_MAIN_PATH

Invalid main clock path selection.

3

-3116

HMICERR_INVALID_CLK_FBK_PATH

Invalid fallback clock path selection.

3

-3117

HMICERR_INVALID_HMIC_REFERENCE

Invalid HMIC number.

3

-3118

HMICERR_CLOCK_UPDATE_BUSY

Unable to lock HMIC data.

3

-3119

HMICERR_UNKNOWN_H100_MASTER

Invalid selection for master mode.

3

-3120

HMICERR_UNKNOWN_FBK_MODE

Invalid selection for fallback mode.

3

-3121

HMICERR_UNKNOWN_LSCX_OUTPUT

Invalid LSCX stream.

3

-3122

HMICERR_UNKNOWN_LSCX_CHOICE

Invalid LSCX signal.

3

-3123

HMICERR_UNKNOWN_FG_PIN_CFG

Invalid frame group configuration.

3

-3124

HMICERR_UNKNOWN_FG_SPEED

Invalid frame group speed.

3

-3125

HMICERR_UNKNOWN_FG_WIDTH

Invalid frame group width.

3

-3126

HMICERR_UNRECOGNIZED_REG

Invalid register.

3


AG clock manager errors

When the error code returned is -9, the error is a clock manager error. In this case, the error includes a hexadecimal string that indicates the type of clock manager error that occurred. For example:

9a00    200    0    0 11:32:07.02   2:  -9.    dc7

In this example, the error type is 9a00 with a -9 error code. Therefore it is a clock manager error. The dc7 hexadecimal string shows that the error is BDCFG_ERR_SM_CLOCK_CFG_FAILS. This error indicates that there was a failure when the clock fallback state machine issued a command.

The following table lists clock manager errors:

Hex

Error name

Description

Category

0x0D80

CLK_MGR_ERR_INVALID_PARAMETER

Parameters passed to function do not match requirements.

3

0x0D81

CLK_MGR_ERR_ILLEGAL_CLK_INDEX

Framer INDEX outside range of valid framers.

3

0x0D82

CLK_MGR_ERR_PREV_CLK_DEFINED

A framer instance already exists at this index.

3

0x0D83

CLK_MGR_ERR_UNRECOG_CLK_TYPE

Tried to create an invalid framer type. Framer type must be T1 or E1.

3

0x0D84

CLK_MGR_ERR_NO_CONFIG_BUF

No configuration buffer to send to init code.

3

0x0D85

CLK_MGR_ERR_NOT_INITIALIZED

Default error results are set to this.

3

0x0D86

CLK_MGR_ERR_NO_BUF

Command expected a buffer and none present.

3

0x0D87

CLK_MGR_ERR_UNABLE_TO_ENABLE_IRQ

Could not hook into IRQ chain.

3

0x0D88

CLK_MGR_ERR_UNABLE_TO_START_1SEC_THREAD

Unable to start thread for 1 second process.

3

0x0D89

CLK_MGR_ERR_UNABLE_TO_START_IRQ_THREAD

Unable to start thread for 1 second process.

3

0x0D8A

CLK_MGR_ERR_UNABLE_TO_CREATE_1SEC_LIST

Unable to create new function list for 1 second process.

3

0x0D8B

CLK_MGR_ERR_UNABLE_TO_CREATE_IRQ_LIST

Unable to create new function list for IRQ process.

3

0x0D8C

CLK_MGR_ERR_UNABLE_TO_CREATE_EVENT_HDL

Unable to create event handle for IRQ DPC code.

3

0x0D8D

CLK_MGR_ERR_UNABLE_TO_CREATE_DPC_LIST

Unable to create list to handle DPCs.

3

0x0D8E

CLK_MGR_ERR_UNABLE_TO_CREATE_BDCLKCFG

Unable to create or get handle for BD_CLK_CFG.

3

0x0D8F

CLK_MGR_ERR_UNABLE_TO_CREATE_CLOCKSM

Unable to create or get handle for CLOCKSM.

3

0x0D90

CLK_MGR_ERR_UNABLE_TO_CREATE_CRIT_SECT

Unable to create critical section for CLOCKSM.

3

0x0D91

CLK_MGR_ERR_UNABLE_TO_GET_CRIT_SECT

Timed out getting CLOCKSM critical section.

3

0x0DC0

BDCFG_ERR_NO_HMIC_FOUND

No HMIC found.

2

0x0DC1

BDCFG_ERR_UNRECOG_PARAMETER

Invalid clocking parameter.

3

0x0DC2

BDCFG_ERR_BAD_CTBUS_CLOCK_SRC

Clock source to be used was in alarm.

5

0x0DC3

BDCFG_ERR_ONLY_SUPPORT_8KHZ

NETREF signals on this board support only 8 kHz operation.

4

0x0DC4

BDCFG_ERR_NO_NETWORK_INSTANCE

Clock source to be used does not exist or is not configured.

5

0x0DC5

BDCFG_ERR_CLOCK_SOURCE_IN_ALARM

Clock source to be used was in alarm.

5

0x0DC6

BDCFG_ERR_NO_MVIP_CLK_SUPPORT

No MVIP bus support.

4

0x0DC7

BDCFG_ERR_SM_CLOCK_CFG_FAILS

Failed when clock fallback state machine issued command.

3

0x0DC8

BDCFG_ERR_NO_NETREF_ON_WDOG

Failed to detect NETREF signal on I/O after configured to drive the signal.

5

0x0DC9

BDCFG_ERR_CANNOT_GET_CLK_REG_HNDL

Failed to get handle to write HMIC registers.

3

0x0DCA

CLKSM_ERR_STANDALONE_NO_SRC

Both clock sources failed while running standalone mode.

5

0x0DCB

CLKSM_ERR_PRIMARY_NO_SRC

Both clock sources failed while running primary mode.

5

0x0DCC

CLKSM_ERR_SECONDARY_NO_SRC

Both clock sources failed while running secondary mode.

5

0x0DCD

CLKSM_ERR_SLAVE_NO_SRC

Both clock sources failed while running slave mode.

5

0x0DCE

BDCFG_ERR_LREF_PREVIOUS_IN_USE

LREF previously in use - clocking restriction.

4