This topic describes:
Power requirements including the telco power per board
|
Feature |
Specification |
|---|---|
|
TDM Bus |
Features one complete H.100 bus interface with MVIP-95 enhanced-compliant switching |
|
Processing power |
One TMS320C549 DSP |
|
Board weight |
Main board: .50 lb (.18 kg) Daughterboard: .15 lb (.08 kg) |
|
Software |
Natural Access |
|
Feature |
Specification |
|---|---|
|
Electrical |
5 V PCI bus interface compliant with the PCI specification, version 2.2. The PCI interface is a 33 MHz, 32-bit target device |
|
Mechanical |
Designed to the PCI specification |
|
Bus Speed |
33 MHz maximum |
|
I/O Mapped Memory |
Memory mapped interface for efficient block data transfers |
|
Addresses/Interrupts |
Automatically configured by PCI BIOS (no jumpers or switches) |
|
BIOS |
Required conformance to PCI specification version 2.2 |
At the end of the adapter cable on the CX 2000 board, there are two RJ-21 connectors with 24 circuits on the first, and eight circuits on the second. Refer to Connecting to station telephones for the RJ-21 connector pinouts and the ring pin and tip pin table.
Switchable access to any of 4096 H.100 timeslots.
H.100 clock master or clock slave (software-selectable).
Compatible with any H.100-compliant telephony interface.
|
Feature |
Description |
|---|---|
|
Operating temperature |
0 to 50 degrees C |
|
Storage temperature |
-20 to 70 degrees C |
|
Humidity |
5% to 80%, non-condensing |
|
Thermometer ID |
In temperature controlled laboratory environment |
In the field |
|---|---|---|
|
0 |
65° C |
90° C |
|
1 |
65° C |
90° C |
|
2 |
60° C |
90° C |
|
3 |
60° C |
90° C |
|
4 |
60° C |
90° C |
For more information, refer to Verifying the board's operating temperature.
|
State |
Requirement |
|---|---|
|
BD_SEL# Active/CX 2000 Active |
1 A maximum @ 5 V |
|
Input power |
Current |
Maximum voltage |
|---|---|---|
|
-24 to-30 V DC (low battery) |
1.0 A maximum |
30.5 V DC |
|
-24 to -48 V DC (high battery) |
1.0 A maximum (with 32 stations active) |
52.0 V DC |
|
Ring voltage |
0.25 A (with 20 ports active) |
92.0 V AC, 52.0 V DC |
|
Specification |
Value |
|---|---|
|
Return loss (ref. 600 Ohms +2.2 mF standard) |
20 dB minimum (ERL) |
|
4 to 2 wire gain tolerance |
+/- 1 dB |
|
4 to 2 wire gain range |
+6 to -6 dB |
|
2 to 4 wire gain tolerance |
+/- 1 dB |
|
2 to 4 wire gain range |
+6 to -6 dB |
|
Frequency response 300 Hz - 3200 Hz. reference to 1 kHz |
+/- 1 dB |
|
Trans-hybrid loss |
20 dB minimum @ 300 Hz - 3400 Hz into 600 Ohms |
|
Signal overload level |
+3 dBm at 0 dB gain |
|
T-R input impedance (300 - 3200 Hz) |
600 Ohms |
|
Idle channel noise through connection |
< 20 dB rnC |
|
Crosstalk transmit to receive channels |
< -70 dB @ 1 kHz |
|
Operating loop current |
Maximum: 25 to 30 mA |
|
Maximum ringer equivalence load |
1.5 |
|
Ringing voltage output |
CX 2000 power supply module: 86 V AC, -48 V DC |
The specifications in this topic apply to the NMS rack mount ringing power supply.
|
Description |
A 19" w x 5.25" h rack mount chassis containing four separate modules, each rated for 2.2 A (DC) and 0.1 7 A (DC) output current. The modules operate in a parallel mode output current. |
|
Input power |
90-132/180-264 V AC 47-63 Hz automatic range selection. |
|
DC output |
24V DC/ 30 V DC and -48 V DC @ 2.2 A/module total. |
|
DC output regulation |
Less than 1%. |
|
DC output ripple |
Less than 0.5% peak to peak. |
|
Output isolation |
24 V DC and -48 V DC isolated from chassis ground. AC output is referenced by -48 V DC output. |
|
AC output |
0.17A/module with 100% duty cycle. |
|
AC output frequency |
17, 20, 25, or 50 Hz +/-1 0% switch selectable. |
|
AC output regulation |
Less than 10% for the full input voltage range and no load to full load. 90 V AC maximum. |
|
AC output wave form |
Simulated sine wave with less than 20% distortion. |
|
Current limiting |
All outputs have current limiting with full protection and auto recovery. |
|
Output indicator |
Green LED on the module indicates that all outputs are operating. External signal indicates an alarm condition. |
|
Module failure protection |
A failure in any module results in its outputs being automatically taken offline. |
|
Temperature range |
Ambient temperature range is 0 to 50 degrees C for full load operation. |
|
EMI design standards |
Approved to FCC 20780, Part 15, Class B, EN55022, Class B, and EN50082-1. |
|
Safety design standards |
Approved to EN60950, UL1950 3rd edition and 1/24/00 CSA C22.2-950. |
The following illustration shows the NMS power supply pinouts:

The mating connector is Positronics PLBO8M0050 with MC116N pins.