Software differences: AG 4040C to CG 6060C

The application differences between the AG 4040C and CG 6060C boards include:

ADI board type

AG 4040C board

CG 6060C board

ADI boardtype = ADI_BOARDTYPE_AG4000C_XX

where XX represents 4T, 4E, 2T, or 2E

Note: At the ADI and NCC levels, the AG 4040C board is identified as an AG 4000C board.

ADI boardtype = ADI_BOARDTYPE_CG6060C


Switch model

Item

AG 4040C board

CG 6060C board

Conferencing streams

32 and 33

68 and 69

DSP signaling streams

18 and 19

66 and 67 and cannot be connected to the CT bus.

DSP voice streams

16 and 17

64 and 65

Echo canceling streams

34 and 35

70 and 71

HDLC pseudo streams (for AG 4000 compatibility)

20-27

No HDLC pseudo streams.

HDLC switching connections

To support existing AG 4000 applications on an AG 4040C board, legacy HDLC switching connections are accepted without error, but they have no functional impact on the board.

Legacy HDLC switching connections are not supported.


Note: The CG boards use the same switch device name as AG boards, agsw.

Echo API

AG 4040C board

CG 6060C board

Supports adiCommandEchoCanceller and adiModifyEchoCanceller.

Supports adiCommandEchoCanceller and adiModifyEchoCanceller only if DSP-based echo canceling is used.

If hardware echo canceling is used, individual channels can be enabled and disabled using swiConfigLocalTimeslot.