Verifying the board's operating temperature

The CX Devices Interface (CDI) service provides API functions for temperature monitoring on CX 2000 boards. Refer to the CDI Service Developer's Reference Manual for information about these functions.

Readings should be taken after running under a typical load (with a number of stations off-hook) for one hour. The following table indicates the maximum safe operating temperatures for various environments:

On-board temperature sensor ID

Maximum temperature reading in temperature controlled laboratory environment

Maximum field operating temperature

0

65° C

90° C

1

65° C

90° C

2

60° C

90° C

3

60° C

90° C

4

60° C

90° C


Exceeding these readings will cause warnings of overheating. Reduce the temperature in one of the following ways:

CX boards that operate beyond the maximum field operating temperatures may exhibit one or more of the following symptoms: