This topic describes:
Power requirements including the telco power per board
|
Feature |
Description |
|
TDM Bus |
Features one complete H.110 bus interface with MVIP-95 enhanced-compliant switching |
|
Processing power |
One TMS320C549 DSP |
|
Board weight |
Main board: .65 lb (.28 kg) Daughterboard: .15 lb (.08 kg) Rear transition board: .60 lb (.24 kg) |
|
Software |
Natural Access |
|
Feature |
Specification |
|---|---|
|
Electrical |
CompactPCI bus designed to CompactPCI PICMG specification revision 2.1 |
|
Mechanical |
Designed to the CompactPCI PICMG specifications revision 2.1 for 6U style boards |
|
Bus Speed |
33 MHz maximum |
|
I/O Mapped Memory |
Memory mapped interface for efficient block data transfers |
|
Addresses/Interrupts |
Automatically configured by CompactPCI BIOS (no jumpers or switches) |
On the rear I/O transition board for the CX 2000C board, there are two RJ-21 connectors with 24 circuits on the first connector and either 8 (for CX 2000C-32) or 24 (for CX 2000C-48) circuits on the second connector. Refer to Cable connections for information on the pin assignments.
Switchable access to any of 4096 H.110 timeslots.
H.110 clock master or clock slave (software-selectable).
Compatible with any H.110-compliant telephony interface.
|
Feature |
Description |
|---|---|
|
Operating temperature |
0 to 50 degrees C |
|
Storage temperature |
-20 to 70 degrees C |
|
Humidity |
5% to 80%, non-condensing |
|
Thermometer ID |
In temperature controlled laboratory environment |
In the field |
|---|---|---|
|
0 |
65° C |
95° C |
|
1 |
65° C |
95° C |
|
2 |
65° C |
95° C |
|
3 |
55° C |
85° C |
|
4 |
60° C |
90° C |
For more information, refer to Verifying the board's operating temperature.
|
Board model |
State |
Requirement |
|---|---|---|
|
CX 2000C-32 and CX 2000C-32-R |
BD_SEL# Active/CX 2000C Active |
500 mA maximum @ 5.0 V 500 mA @ 3.3 V |
|
CX 2000C-48 |
BD_SEL# Active/CX 2000C Active |
750 mA maximum @ 5.0 V 500 mA @ 3.3 V |
|
Input power |
Current |
Maximum voltage |
|---|---|---|
|
-24 to-30 V DC (low battery) |
1.00 A maximum |
30.5 V DC |
|
-24 to -48 V DC (high battery) |
1.00 A maximum (with 32 stations active) |
52.0 V DC |
|
Ring voltage |
0.25 A (with 20 ports active) |
92.0 V AC, 52.0 V DC |
|
Specification |
Value |
|---|---|
|
Return loss (ref. 600 Ohms +2.2 mF standard) |
20 dB minimum (ERL) |
|
4 to 2 wire gain tolerance |
+/- 1 dB |
|
4 to 2 wire gain range |
+6 to -6 dB |
|
2 to 4 wire gain tolerance |
+/- 1 dB |
|
2 to 4 wire gain range |
+6 to -6 dB |
|
Frequency response |
+/- 1 dB |
|
Trans-hybrid loss |
20 dB minimum @ 300 Hz - 3400 Hz into 600 Ohms |
|
Signal overload level |
+3 dBm at 0 dB gain |
|
T-R input impedance |
600 ohms |
|
Idle channel noise through connection |
< 20 dB rnC |
|
Crosstalk transmit to receive channels |
< -70 dB @ 1 kHz |
|
Operating loop current |
Maximum: 25 to 30 mA |
|
Maximum ringer equivalence load |
1.5 |
|
Ringing voltage output |
CX 2000C power supply module: 86 V AC, -48 V DC CX 2000C-32-R (internal ring): 55 V AC, -30 V DC |
|
Specification |
Value |
|---|---|
|
Maximum number of telephones that can ring simultaneously |
12 (for telephones with ringer equivalence = 1.0) |
|
Maximum cable length |
3000 ft |
|
Description |
A 19" w x 5.25" h rack mount chassis containing four separate modules, each rated for 2.2 A (DC) and 0.1 7 A (DC) output current. The modules operate in a parallel mode output current. |
|
Input power |
90-132/180-264 V AC 47-63 Hz automatic range selection. |
|
DC output |
24 V C/ 30 V DC and -48 V DC @ 2.2 A/module total. |
|
DC output regulation |
Less than 1%. |
|
DC output ripple |
Less than 0.5% peak to peak. |
|
Output isolation |
24 V DC and -48 V DC isolated from chassis ground. AC output is referenced by -48 V DC output. |
|
AC output |
0.17 A/module with 100% duty cycle. |
|
AC output frequency |
17, 20, 25, or 50 Hz +/-1 0% switch selectable. |
|
AC output regulation |
Less than 10% for the full input voltage range and no load to full load. 90 V AC maximum. |
|
AC output wave form |
Simulated sine wave with less than 20% distortion. |
|
Current limiting |
All outputs have current limiting with full protection and auto recovery. |
|
Output indicator |
Green LED on the module indicates that all outputs are operating. External signal indicates an alarm condition. |
|
Module failure protection |
A failure in any module results in its outputs being automatically taken offline. |
|
Temperature range |
Ambient temperature range is 0 to 50 degrees C for full load operation. |
|
EMI design standards |
Approved to FCC 20780, Part 15, Class B, EN55022, Class B, and EN50082-1. |
|
Safety design standards |
Approved to EN60950, UL1950 3rd edition and 1/24/00 CSA C22.2-950. |
The following illustration shows the NMS power supply pinouts:
NMS power supply pinouts
The mating connector is Positronics PLBO8M0050 with MC116N pins.