  • Forum Thread: Routing Configuration

    I have 8 diferent SIGTRAN links with 8 diferent GT numbers. Currently we have one NC linked to one SIGTRAN link. We are routing the outbounding packet to the right GT based on NC. But the equipment supports only 4 NCs. The question is how can I configure the Dialogic to route the packet to the right...
  • Forum Reply: RE: ./sctpn: error while loading shared libraries: libsctp.so.1: cannot open shared object file: No such file or directory

    1994-08-01 i have same issue in kali linux, can you help me how to resolve it. i try chroot environment in 64 bit linux and try to run 32 bit but stil same error with sctpn :error while loading shared libraries: libsctp. so. 1 : cant'open etc etc plz help
  • Forum Thread: how to send msg between 2 PCs using SIGTRAN ?

    How to send message between two computers using SIGTRAN protocol on Linux (CentOS 7) ? -I've installed dpklnx package on the two computers.
  • Forum Thread: Is there any documnet describes how to use SIGTRAN to send and receive msgs in linux between 2 PCs?

    HI, I need a document that describes how to send and receive messages usign SIGTRAN between two computers with Linux (Centos 7) ? I need the for learning purposes. Thanks.
  • Forum Thread: Natural Access Board Detection Problem

    Can anyone help me on this? Why is it that my PC could not detect this? I downloaded this for my Windows.
  • Forum Reply: RE: NOT Getting ERB MSG (ERBBCSM) after sending continue MSG to network

    kindly help : how to change NI value in sccp config file in ss7 1145.sccpcfg.txt ================================ ************************************************************************* * * SCCP Configuration. * ************************************************************** * * Issue configuration...
  • Forum Thread: NOT Getting ERB MSG (ERBBCSM) after sending continue MSG to network

    kindly suggest me how to define NI value to sccpcfg.ms7 file NI value 2 (NA=2) already defined in config.txt file as like below formt: SNSLI:SNLINK=1,IPADDR=10.200.3.78,IPADDR2=10.200.3.110,HPORT=2905,PPORT=2910,SNTYPE=m3ua,SNEND=C,NA=2,SG=1; but this value not defined in sccpcfg.ms7 file. when...
  • Forum Thread: How does STP work?

    Hello, I am making a simulation of some MAP dialogue between MSC/VLR and HLR. I need to include one STP in my network. However, I didn't find clear explanations about the STP's way of working. How does it work? Is it related to the routing indicator in the SCCP received message? All I understood...
  • Forum Thread: Test ctu application

    Hi, I want o test CTU application on SPCI4 board. I have a single board of SPCI4. CTU expect that it will receive IAM from some external entity and then CTU will process the IAM and response accordingly. User guide mention about Script to initiate the call. But how to use the script. do I need another...
  • Forum Thread: Sigtran Association not up

    Hi friends, I am getting a problem on my testing environment. I am trying to establish a SIGTRAN association between my 2 PCs but my association is not coming up. I need your help in this regard. below are my logs and my configuration details. I try many of times with little changes like SNEND...
  • Forum Thread: SIP-I injection

    can anyone guide me if there are any stacks for dialogic that could be used to set up a SIP-ISUP stream and manipulate its parameters
  • Forum Thread: ISUP Circuits are blocked

    Hi, I have 4 E1. -> 2 for signalling and -> 2 for Voice circuits. Below is the MTP configuration used. For 2 E1 with signalling it is fine. But for the Other 2 Voice circuit E1s the circuits are blocked. Even ISUP CIC unblocking is not working for the voice links. I have attached the config...
  • Forum Thread: Guidance required on Configuration SS7MD board

    Hi, We have a ss7MD with two E1 Links towards a Single OPC and Single LocalPC. The configuration was working fine for Single E1.So to increase the call capacity we have connected Two E1 to the single Board. SLC for first E1 is 0 and SLC for II E1 is 1. I tried the attached configuration - calls...
  • Forum Reply: RE: error ss7MD Resetting board: board 0 not reset correctly

    Below is from /var/logs/messages/ Aug 23 03:33:01 call1 rsyslogd: [origin software="rsyslogd" swVersion="5.8.10" x-pid="1564" x-info="http://www.rsyslog.com"] rsyslogd was HUPed Aug 23 10:25:24 call1 kernel: ->iph_detach for dev 73e05000 - index 0 - Dev=73e05000...
  • Forum Reply: RE: error ss7MD Resetting board: board 0 not reset correctly

    Hi Below is the output from gctload and dmesg. ---------------gctload------------------------------------------------------ [root@callproxy1 DSI]# ./gctload -d Reading from system configuration file: 'system.txt' Created LOCAL module Id 0x20 Created LOCAL module Id 0x0 Created LOCAL...
  • Forum Thread: error ss7MD Resetting board: board 0 not reset correctly

    Hi Im getting the below error while starting the Dialogic Board, Please Guide S7L:I0000 M t0008 i0000 f20 ddf sd6 Resetting board: board 0 not reset correctly S7MGT: FAILED S7L:I0000 M t06a0 i0000 f20 def s62 p001000d6 Can you guide in solving this. ************************************...
  • Forum Thread: dsistat rsp status 2695 getting stuck

    I would appreciate your kind help please on an issue that I have when I run dsistat as following: Example query on Real node: ./dsistat rsp status 2695 SPC STATE <----------- Stucked here The application displays one line only -> “SPC STATE” and gets freeze. The release...
  • Forum Reply: RE: Dual-Resilient M3UA IPSP and ASP configuration on the same system

    Hi, Thanks to Dialogic who prepared DPK Release 6.4.4 for Windows, this configuration works fine now on this platform. For Linux, it was already supported in 6.6.1. This release allows M3UA to be configured with multiple associations connecting to the same remote Destination Point Code (DPC). This...
  • Forum Thread: Dual-Resilient M3UA IPSP and ASP configuration on the same system

    Hi, We need to implement a solution to support on the same dual-resilient system, both M3UA IPSP and ASP connections. Our system is made up of 2 SCPs sharing the same Point Code. The IPSP connection is towards a single MSS, each SCP having connection to the same MSS. The ASP connection is towards two...
  • Forum Thread: how to run second DNI board

    Hello everyone! ( HMP4.1Lin) I have 2 boards signal board: spci4 (first 3 trunks) voice board: dni310 (4th trunk) in file gcss7.cfg I have: CGrp 0 dkB1 CGrp 1 dkB2 CGrp 2 dkB3 CGrp 3 dtiB1 in file config.txt I have: ISUP_CONFIG 0 0 0x4d 0x0474 4 128 ISUP_CFG_CCTGRP...
  • Forum Thread: SS7 board for integrating with SP

    Hi, I am new to the telecom and dialogic devices. we are in the beginning stage of a new mobile project. It is based on USSD. Now mobile service providers are ready to give SS7 E1 line to my company, and I want to configure a USSD gateway server in my premise. Now the question is, what are the hardwares...
  • Forum Reply: Re: M3UA Trial license throughput limitations ?

    Hi Alaa, Thanks for the Information. One more thing, is this "Throuhput in Kbps: 1232 kbps" is for outgoing traffic only or includes both way traffic (incoming + Outgoing). Regards, Komal Kothari
  • Forum Thread: Is there a support team in Dialogic!!! I'm not getting support!!! I have 8 open calls more then a year! think B 4 you buy Dialogic

    I'm not getting support!!! I have 8 open calls more then a year! think B 4 you buy Case Id Abstract Status Opened Updated View C126691 Expand AbstractRequest to contact Daniel In Progress Dialogic 24-Aug-12 31-Jan-13 View C122012 Few fax calls are failing. In Progress Dialogic 30-Apr-12 07...
  • Forum Thread: ss7HD board Configuration failing - But working for SPCI14

    Hi We have a ss7 SPCI14 working fine with the configuration as below.But the same E1 cable when connected to the ss7hd board its failing . ******************************************************************************** * * Example Protocol Configuration File (config.txt) for use with...
  • Forum Thread: A problem with E1 connected to SPCI4

    Hi everybody, I have faced the following problem. We have 2 servers: Server1 (with working service based on Global Call) and Server2 (which is a test server). Both of them have SPCI4 cards with E1 cables plugged and which connect them to mobile operators MSC . Server1 is already...