L3P BCC Protocol PPL Timers (0x008C)
When specifying new timer values, remember that all PPL Timers are specified in 10 ms increments. For example, a PPL timer for 4 seconds is specified as 4000 (decimal, 400 x 10 ms = 4 seconds), which is the hexadecimal value of (0x190).
|
Timer ID |
Description |
Value (default) |
|---|---|---|
|
0x01 |
Allocation Complete Wait |
1.5 seconds |
|
0x02 |
Deallocation Complete Wait |
2 seconds |
|
0x03 |
Deallocation Complete Wait |
2 seconds |
|
0x04 |
Audit Complete Wait |
1.5 seconds |
|
0x05 |
AN Fault Acknowledge Wait |
1.5 seconds |
|
0x06 |
Waiting for Datalink Connection Establish |
4 seconds |