The following specifications apply to Part Numbers 5399, 5593, 5551, and 5549 rev D.1 and higher:
|
Specification |
Line interface type |
||
|---|---|---|---|
|
|
Loop start |
Subscriber loop |
DID |
|
Connectors |
1 four-ganged, four-position modular connector |
1 four-ganged, four-position modular connector |
1 four-ganged, four-position modular connector |
|
Return loss (ref. 600 Ohms +2.2 uF standard) |
20 dB min. (ERL) |
20 dB min. (ERL) |
20 dB min. (ERL) |
|
Four to two wire gain Tolerance |
+/- 1 dB |
+/- 1 dB |
+/- 1 dB |
|
Four to two wire gain range |
+6 to -6 dB |
+6 to -6 dB |
+6 to -6 dB |
|
Two to four wire gain tolerance |
+/- 1 dB |
+/- 1 dB |
+/- 1 dB |
|
Two to four wire gain range |
+6 to -6 dB |
+6 to -6 dB |
+6 to -6 dB |
|
Frequency response |
+/- .8 dB |
+/- 1 dB |
+/- 1 dB |
|
Trans-hybrid loss |
17 dB min. @ 300 Hz-3.0 kHz into 600 Ohms + 2.2 uF |
17 dB min. @ 300 Hz-2.5 kHz into 600 Ohms + 2.2 uF |
17 dB min. @ 300 Hz-2.5 kHz into 600 Ohms + 2.2 uF |
|
Signal overload level |
+3 dBm at 0 dB gain |
+3 dBm at 0 dB gain |
+3 dBm at 0 dB gain |
|
CMRR |
> 80 dB |
> 50 dB |
> 50 dB |
|
T-R input impedance |
Voice band 600 Ohms +2.2 uF standard |
600 Ohms +2.2 uF standard |
600 Ohms +2.2 uF standard |
|
Idle channel noise through connection |
< 20 dB rnC |
< 20 dB rnC |
< 20 dB rnC |
|
Crosstalk transmit to receive channels |
< -70 dB @ 1 kHz |
< -70 dB @ 1 kHz |
< -70 dB @ 1 kHz |
|
T-R isolation to SELV |
>1500VRMS |
Not applicable. |
Not applicable. |
|
Off-hook detect |
Guaranteed Detect: Guaranteed No Detect: |
Guaranteed Detect: Guaranteed No Detect: |
Guaranteed Detect: Guaranteed No Detect: |
|
Operating loop current |
18 mA to 70 mA |
13 mA to 31 mA |
13 mA to 31 mA |
|
Loop current and polarity detect |
Single bit indicates if the current is flowing from Tip to Ring or Ring to Tip. |
Not applicable. |
Not applicable. |
|
Ring detection |
Guaranteed Detect: Guaranteed No Detect: |
Not applicable. |
Not applicable. |
|
Maximum cable distance: |
Not applicable. |
|
|
|
At 48 V, 24 AWG |
|
18,000 feet (5 km) |
18,000 feet (5 km) (1800 Ohms) |
|
At 30 V, 24 AWG |
|
2,000 feet (600 m) |
Not applicable. |
|
Maximum ringer equivalence load |
Not applicable. |
1.5 |
Not applicable. |
European models change only where required to conform to regulation TBR21 (loop start only). For example, T-R input impedance is 270 Ohms in series with a parallel combination of 750 Ohms and 150 uF.