Signaling module electrical specifications

 

Common specifications (United States version)

The following specifications apply to Part Numbers 5399, 5593, 5551, and 5549 rev D.1 and higher:

Specification

Line interface type

 

Loop start

Subscriber loop

DID

Connectors

1 four-ganged, four-position modular connector
(4 RJ-14x jacks).

1 four-ganged, four-position modular connector
(4 RJ-14x jacks).

1 four-ganged, four-position modular connector
(4 RJ-14x jacks).

Return loss (ref. 600 Ohms +2.2 uF standard)

20 dB min. (ERL)

20 dB min. (ERL)

20 dB min. (ERL)

Four to two wire gain Tolerance

+/- 1 dB

+/- 1 dB

+/- 1 dB

Four to two wire gain range

+6 to -6 dB

+6 to -6 dB

+6 to -6 dB

Two to four wire gain tolerance

+/- 1 dB

+/- 1 dB

+/- 1 dB

Two to four wire gain range

+6 to -6 dB

+6 to -6 dB

+6 to -6 dB

Frequency response
300 Hz - 3200 Hz. Reference to 1 kHz

+/- .8 dB

+/- 1 dB

+/- 1 dB

Trans-hybrid loss

17 dB min. @ 300 Hz-3.0 kHz into 600 Ohms + 2.2 uF

17 dB min. @ 300 Hz-2.5 kHz into 600 Ohms + 2.2 uF

17 dB min. @ 300 Hz-2.5 kHz into 600 Ohms + 2.2 uF

Signal overload level

+3 dBm at 0 dB gain

+3 dBm at 0 dB gain

+3 dBm at 0 dB gain

CMRR

> 80 dB

> 50 dB

> 50 dB

T-R input impedance
(300 - 3200 Hz)

Voice band 600 Ohms +2.2 uF standard

600 Ohms +2.2 uF standard

600 Ohms +2.2 uF standard

Idle channel noise through connection

< 20 dB rnC

< 20 dB rnC

< 20 dB rnC

Crosstalk transmit to receive channels

< -70 dB @ 1 kHz

< -70 dB @ 1 kHz

< -70 dB @ 1 kHz

T-R isolation to SELV

>1500VRMS

Not applicable.

Not applicable.

Off-hook detect

Guaranteed Detect:
Current > 10 mA

Guaranteed No Detect:
Current < 3.3 mA

Guaranteed Detect:
Current > 13 mA

Guaranteed No Detect:
Current < 7 mA

Guaranteed Detect:
Current > 13 mA

Guaranteed No Detect:
Current < 7 mA

Operating loop current

18 mA to 70 mA

13 mA to 31 mA

13 mA to 31 mA

Loop current and polarity detect

Single bit indicates if the current is flowing from Tip to Ring or Ring to Tip.

Not applicable.

Not applicable.

Ring detection

Guaranteed Detect:
30 VRMS 17 - 33 Hz (US version)

Guaranteed No Detect:
No detect <15 VRMS (0 - 5 kHz)

Not applicable.

Not applicable.

Maximum cable distance:

Not applicable.

 

 

At 48 V, 24 AWG

 

18,000 feet (5 km)
(1800 Ohms)

18,000 feet (5 km) (1800 Ohms)

At 30 V, 24 AWG

 

2,000 feet (600 m)
(600 Ohms)

Not applicable.

Maximum ringer equivalence load

Not applicable.

1.5

Not applicable.


European models change only where required to conform to regulation TBR21 (loop start only). For example, T-R input impedance is 270 Ohms in series with a parallel combination of 750 Ohms and 150 uF.