ADI_DIAL_PARMS

Dependent function: adiStartDial

Field name

Type

Default

Units

Description

breaktime

DWORD

60

ms

Break (on-hook) duration for dial pulses.

Valid AG board and CG board range is 0 through 30000.

dialtonewait

DWORD

5000

ms

Maximum time to wait for dial tone (; character).

Valid range is 0 through 65535.

dtmfampl1

INT32

-6

dBm

Amplitude of the low frequency component of the DTMF pair.

Valid AG board and CG board range is -54 through -3.

dtmfampl2

INT32

-4

dBm

Amplitude of the high frequency component of the DTMF pair.

Valid AG board and CG board range is -54 through -3.

dtmfofftime

DWORD

80

ms

Duration of the silence time between each digit.

Valid AG board and CG board range is 0 through 65534.

dtmfontime

DWORD

80

ms

Duration of each DTMF or MF digit.

Valid AG board and CG board range is 0 through 65534.

flashtime

DWORD

500

ms

Amount of time to assert the on-hook signaling pattern for a flash (! character).

Valid AG board and CG board range is 0 through 65535.

interpulse

DWORD

700

ms

Inter-digit time for pulsed dialing.

Valid AG board and CG board range is 0 through 30000.

longpause

DWORD

5000

ms

Amount of delay associated with the . (period) character.

Valid range is 0 through 65535.

maketime

DWORD

40

ms

Make (off-hook) duration for dial pulses.

Valid AG board and CG board range is 0 through 30000.

method

DWORD

0

mask

Type of signaling.

  • 0=DTMF

  • 1=Pulse

  • 2=MF (US)

reserved

DWORD

0

internal

Do not modify.

shortpause

DWORD

2000

ms

Amount of delay associated with the , (comma) character.

Valid range is 0 through 65535.

tonebandw1

DWORD

40

Hz

Bandwidth of the first frequency of the dial tone detector.

Valid AG board and CG board range is 20 through 800.

tonebandw2

DWORD

40

Hz

Bandwidth of the second frequency of the dial tone detector.

Valid AG board and CG board range is 20 through 800.

tonefreq1

DWORD

350

Hz

First (or only) dial tone frequency.

Valid AG board and CG board range is 330 through 3600.

tonefreq2

DWORD

440

Hz

Second dial tone frequency. Set this value to 0 (zero) to detect a single frequency.

Valid AG board and CG board range is 330 through 3600.

tonequalampl

INT32

-28

dBm

Minimum signal amplitude to qualify for dial tone detection.

Valid AG board and CG board range is -40 through 0.

tonequaltime

DWORD

50

ms

Minimum duration of a qualified tone to be considered dial tone.

Valid range is 0 through 32767.

tonereflevel

DWORD

0xB000

IDU

Do not modify.

tonetotaltime

DWORD

0

ms

Detects interrupted dial tones (stuttered dial tone) in certain countries. Defaults to 0 (zero), which indicates that dialing can proceed as soon as a dial tone is detected without waiting for stuttered dial tone to end.

If set to a non-zero value, the value represents the total qualification time for dial tone, and the following occurs:

  • Only precise dialtone detection is used.

  • If dialtone disappears, requalify until dialtonewait expires.

  • If dialtone lasts for totaltime, proceed with dialing.