ADI_FSKRECEIVE_PARMS

Dependent function: adiStartReceivingFSK

Field name

Type

Default

Units

Description

baudrate

DWORD

1200

integer

Transmission baud rate. 1200 is the only valid value.

droptime

DWORD

5

ms

Minimum dropout to silence before a packet is considered terminated.

minlevel

INT32

-35

dBm

Required minimum receive level.

minmark

DWORD

10

ms

Minimum required initial mark and seizure time.