Field name |
Type |
Default |
Units |
Description |
|---|---|---|---|---|
|
ampl1 |
INT32 |
-20 |
dBm |
Amplitude of the first (or only) frequency component. Valid AG board and CG board range is -54 through 3. |
|
ampl2 |
INT32 |
0 |
dBm |
Amplitude of the second frequency component, if any. Valid AG board and CG board range is -54 through 3. |
|
freq1 |
DWORD |
1000 |
Hz |
First (or only) frequency of the generated tone. Valid range is 200 through 3600. |
|
freq2 |
DWORD |
0 |
Hz |
Second frequency of the generated tone, or 0 if the tone is a single frequency. If not 0, valid range is 200 through 3600. |
|
iterations |
INT32 |
1 |
integer |
Number of times to repeat the alternating tone and silence period. A count of -1 means repeat forever. Otherwise the valid range is 1 through 32767. |
|
offtime |
DWORD |
0 |
ms |
Duration of silence between tones. Specify 0 for no off time. Valid AG board and CG board range is 0 through 65535. |
|
ontime |
DWORD |
200 |
ms |
Duration of the tone. Valid AG board and CG board range is 1 through 65535. |