AG error types

AG boards record boot time and runtime errors in the agpierror.log file. By default, agpierror.log is located in \nms\oam\log (for Windows) and in /opt/nms/oam/log (for UNIX).

AG boards return the following types of errors, depending on the problem encountered:

Error type

Description

8000

System errors (not channel specific)

8100

DSP driver errors

8200

System errors (channel specific)

8400

TCP manager errors (not channel specific)

8500

GTP engine errors (not channel specific)

9a00

HMIC errors

9900

Digital line and clocking errors

8d00

Voice Message service errors

9100

DSP service layer errors

FF00

Host driver errors

Topics in this section contain AG error messages in table format organized by error type. Refer to the specific error code table for the error code, error name, description, and category of each error message.

For information about the format of the error message, refer to AG error format.

Error categories

The Category column in each error code table uses the numerals 1 through 5 to describe the cause of the error message. The following table defines the categories of returned errors:

Category

Description

1

Application or programming error.

2

Serious board problem. Contact NMS Communications.

3

Serious internal error. Contact NMS Communications.

4

Software configuration error. Check the current configuration, and modify as required.

5

Hardware configuration error. Check cables and connectors.