Error types 9900

The following table lists the 9900 (digital line and clocking) errors:

Error code

Error name

Description

Category

-2049

AGLCERR_LOCK_FAILED

Failed to wait for a resource.

3

-2050

AGLCERR_UNLOCK_FAILED

Failed to unload a semaphore.

3

-2051

AGLCERR_NOT_READY

Interrupt processing failed.

3

-2055

AGLCERR_INVALID_TRUNK

Trunk is out of range.

3

-2056

AGLCERR_INVALID_CHANNEL

Tried to configure a channel which is out of range.

3

-2057

AGLCERR_LOOPBACK_NOT_SUPPORTED

Requesting a loopback is an error since framer does not support per channel loopback.

3

-2058

AGLCERR_CANNOT_CHANGE_FRAME

Frame type cannot be changed on the fly.

3

-2059

AGLCERR_INVALID_PARAMETER

Invalid parameter passed to configuration functions (for example, framer, line code, line type).

3

-2060

AGLCERR_ASSERT

Received unexpected messages.

3

-2061

AGLCERR_MONITOR_DELAY

Interrupt processing procedure takes more than one second.

3

-2062

AGLCERR_MONITOR_FAILED

Lock failed more than two times. Monitor task should exit.

3

-2063

AGLCERR_REG_CHECK_FAILED

Reading indirect base returned an unexpected value.

3

-2064

AGLCERR_POLL_FAILED

Not used.

3

-2065

AGLCERR_UNEXPECTED_INTERRUPT

Received an unexpected E1/T1 interrupt while processing interrupts.

3

-2066

AGLCERR_UNKNOWN_BOARDTYPE

AGLC initialized with an unknown board type.

3

-2067

AGLCERR_IBCD_UNEXPECTED

Pertains to the second parameter. One of the following occurred:

  • Already activated. Missed assert.

  • Loopback not activated.

  • Missed assert. Do not deactivate because may have received a deassert deactivate at the same time as an assert activate (if the two interrupts came at the same time).

3

-2068

AGLCERR_LOOPBACK_FAILED

Failed to configure loopback.

3

-2069

AGLCERR_LOOPBACK_CONFLICT

Loopback already exists.

3

-2070

AGLCERR_TOO_MANY_INTERRUPTS

More interrupts than can be handled.

3

-2071

AGLCERR_PARAM_FILE_CONFLICT

Parameter file conflict. Second parameter is ((option << 16) | T1/E1_RCV_OPT_VERSION_NUMBER)).

3

-2072

AGLCERR_INVALID_BER_THRESHOLDS

BER alarm threshold is less than BER alarm off threshold.

3

-2073

AGLCERR_MONITOR_RUNNING

AGLC manager error. Monitor already running.

3

-2074

AGLCERR_MONITOR_INACTIVE

AGLC manager error. Monitor currently inactive.

3

-2075

AGLCERR_SEND_FAILED

Received an unexpected E1/T1 interrupt while processing interrupts.

3

-2077

AGLCERR_BAD_PARM_COUNT

Alarm registration failed. Wrong parameter count.

3

-3072

HMICERR_LIBRARY_NOT_USABLE

Not used.

3

-3073

HMICERR_LIBRARY_NOT_INITIALIZED

Not used.

3

-3074

HMICERR_LOCK_CREATION_FAILED

Could not create AMX resource semaphore for HMIC.

3

-3075

HMICERR_LOCK_FAILED

Could not lock HMIC resource semaphore.

3

-3076

HMICERR_UNLOCK_FAILED

Failed to unlock HMIC resource semaphore.

3

-3077

HMICERR_DELAY_FAILED

Frame delay failed.

3

-3078

HMICERR_CONNECT_REFERENCE_CNT

Not used.

3

-3079

HMICERR_INVALID_BUS

Bus is invalid.

3

-3080

HMICERR_INVALID_STREAM

Stream is invalid.

3

-3081

HMICERR_INVALID_TIMESLOT

Timeslot is invalid.

3

-3082

HMICERR_INVALID_CLOCK_PARM

Not used.

3

-3083

HMICERR_INVALID_MODE

Framed connect mode is invalid if MVIP is in connect mode, and vice versa.

3

-3084

HMICERR_INVALID_PARAMETER

Physical address received as source while breaking connection.

3

-3085

HMICERR_NO_PATH

Failed to make a connection to DSP driver.

3

-3086

HMICERR_SWICH_VERIFY_FAILED

Switch number passed from the DSP driver is greater than number of secondary HMICs.

3

-3087

HMICERR_CONNECT_NOT_SUPPORTED

This error is returned if one of the following was true while making or breaking a mapping:

  • Physical address is already mapped to a logical address.

  • Mapping from one secondary HMIC to another.

  • Mapping logical to logical.

3

-3088

HMICERR_MODE_NOT_SUPPORTED

HSEC8K_DRIVEN_BY_OSC mode for configuring sec8k clock is not supported.

3

-3089

HMICERR_MVIP_NOT_ENABLED

Failed to configure HMIC clock because MVIP is not enabled.

3

-3090

HMICERR_INVALID_MAP

Not used.

3

-3091

HMICERR_LOCAL_NOT_ENABLED

Local is not enabled. Informational message.

3

-3092

HMICERR_HW_INTERFACE_FAIL

Unknown mode (not framed connect or connect).

3

-3093

HMICERR_CONSUME_MESSAGE

Not used.

3

-3110

HMICERR_NO_RESOURCE

No free entries in HMIC mapping database.

3

-3111

HMICERR_INVALID_CLK_MAIN_SRC

Invalid clock source.

3

-3112

HMICERR_INVALID_CLK_FBK_SRC

Invalid fallback source.

3

-3113

HMICERR_INVALID_CLK_NTREF1_SRC

Invalid NETREF1 source.

3

-3114

HMICERR_INVALID_CLK_NTREF2_SRC

Invalid NETREF2 source.

3

-3115

HMICERR_INVALID_CLK_MAIN_PATH

Invalid main clock path selection.

3

-3116

HMICERR_INVALID_CLK_FBK_PATH

Invalid fallback clock path selection.

3

-3117

HMICERR_INVALID_HMIC_REFERENCE

Invalid HMIC number.

3

-3118

HMICERR_CLOCK_UPDATE_BUSY

Unable to lock HMIC data.

3

-3119

HMICERR_UNKNOWN_H100_MASTER

Invalid selection for master mode.

3

-3120

HMICERR_UNKNOWN_FBK_MODE

Invalid selection for fallback mode.

3

-3121

HMICERR_UNKNOWN_LSCX_OUTPUT

Invalid LSCX stream.

3

-3122

HMICERR_UNKNOWN_LSCX_CHOICE

Invalid LSCX signal.

3

-3123

HMICERR_UNKNOWN_FG_PIN_CFG

Invalid frame group configuration.

3

-3124

HMICERR_UNKNOWN_FG_SPEED

Invalid frame group speed.

3

-3125

HMICERR_UNKNOWN_FG_WIDTH

Invalid frame group width.

3

-3126

HMICERR_UNRECOGNIZED_REG

Invalid register.

3