The following table lists the 9900 (digital line and clocking) errors:
|
Error code |
Error name |
Description |
Category |
|---|---|---|---|
|
-2049 |
AGLCERR_LOCK_FAILED |
Failed to wait for a resource. |
3 |
|
-2050 |
AGLCERR_UNLOCK_FAILED |
Failed to unload a semaphore. |
3 |
|
-2051 |
AGLCERR_NOT_READY |
Interrupt processing failed. |
3 |
|
-2055 |
AGLCERR_INVALID_TRUNK |
Trunk is out of range. |
3 |
|
-2056 |
AGLCERR_INVALID_CHANNEL |
Tried to configure a channel which is out of range. |
3 |
|
-2057 |
AGLCERR_LOOPBACK_NOT_SUPPORTED |
Requesting a loopback is an error since framer does not support per channel loopback. |
3 |
|
-2058 |
AGLCERR_CANNOT_CHANGE_FRAME |
Frame type cannot be changed on the fly. |
3 |
|
-2059 |
AGLCERR_INVALID_PARAMETER |
Invalid parameter passed to configuration functions (for example, framer, line code, line type). |
3 |
|
-2060 |
AGLCERR_ASSERT |
Received unexpected messages. |
3 |
|
-2061 |
AGLCERR_MONITOR_DELAY |
Interrupt processing procedure takes more than one second. |
3 |
|
-2062 |
AGLCERR_MONITOR_FAILED |
Lock failed more than two times. Monitor task should exit. |
3 |
|
-2063 |
AGLCERR_REG_CHECK_FAILED |
Reading indirect base returned an unexpected value. |
3 |
|
-2064 |
AGLCERR_POLL_FAILED |
Not used. |
3 |
|
-2065 |
AGLCERR_UNEXPECTED_INTERRUPT |
Received an unexpected E1/T1 interrupt while processing interrupts. |
3 |
|
-2066 |
AGLCERR_UNKNOWN_BOARDTYPE |
AGLC initialized with an unknown board type. |
3 |
|
-2067 |
AGLCERR_IBCD_UNEXPECTED |
Pertains to the second parameter. One of the following occurred:
|
3 |
|
-2068 |
AGLCERR_LOOPBACK_FAILED |
Failed to configure loopback. |
3 |
|
-2069 |
AGLCERR_LOOPBACK_CONFLICT |
Loopback already exists. |
3 |
|
-2070 |
AGLCERR_TOO_MANY_INTERRUPTS |
More interrupts than can be handled. |
3 |
|
-2071 |
AGLCERR_PARAM_FILE_CONFLICT |
Parameter file conflict. Second parameter is ((option << 16) | T1/E1_RCV_OPT_VERSION_NUMBER)). |
3 |
|
-2072 |
AGLCERR_INVALID_BER_THRESHOLDS |
BER alarm threshold is less than BER alarm off threshold. |
3 |
|
-2073 |
AGLCERR_MONITOR_RUNNING |
AGLC manager error. Monitor already running. |
3 |
|
-2074 |
AGLCERR_MONITOR_INACTIVE |
AGLC manager error. Monitor currently inactive. |
3 |
|
-2075 |
AGLCERR_SEND_FAILED |
Received an unexpected E1/T1 interrupt while processing interrupts. |
3 |
|
-2077 |
AGLCERR_BAD_PARM_COUNT |
Alarm registration failed. Wrong parameter count. |
3 |
|
-3072 |
HMICERR_LIBRARY_NOT_USABLE |
Not used. |
3 |
|
-3073 |
HMICERR_LIBRARY_NOT_INITIALIZED |
Not used. |
3 |
|
-3074 |
HMICERR_LOCK_CREATION_FAILED |
Could not create AMX resource semaphore for HMIC. |
3 |
|
-3075 |
HMICERR_LOCK_FAILED |
Could not lock HMIC resource semaphore. |
3 |
|
-3076 |
HMICERR_UNLOCK_FAILED |
Failed to unlock HMIC resource semaphore. |
3 |
|
-3077 |
HMICERR_DELAY_FAILED |
Frame delay failed. |
3 |
|
-3078 |
HMICERR_CONNECT_REFERENCE_CNT |
Not used. |
3 |
|
-3079 |
HMICERR_INVALID_BUS |
Bus is invalid. |
3 |
|
-3080 |
HMICERR_INVALID_STREAM |
Stream is invalid. |
3 |
|
-3081 |
HMICERR_INVALID_TIMESLOT |
Timeslot is invalid. |
3 |
|
-3082 |
HMICERR_INVALID_CLOCK_PARM |
Not used. |
3 |
|
-3083 |
HMICERR_INVALID_MODE |
Framed connect mode is invalid if MVIP is in connect mode, and vice versa. |
3 |
|
-3084 |
HMICERR_INVALID_PARAMETER |
Physical address received as source while breaking connection. |
3 |
|
-3085 |
HMICERR_NO_PATH |
Failed to make a connection to DSP driver. |
3 |
|
-3086 |
HMICERR_SWICH_VERIFY_FAILED |
Switch number passed from the DSP driver is greater than number of secondary HMICs. |
3 |
|
-3087 |
HMICERR_CONNECT_NOT_SUPPORTED |
This error is returned if one of the following was true while making or breaking a mapping:
|
3 |
|
-3088 |
HMICERR_MODE_NOT_SUPPORTED |
HSEC8K_DRIVEN_BY_OSC mode for configuring sec8k clock is not supported. |
3 |
|
-3089 |
HMICERR_MVIP_NOT_ENABLED |
Failed to configure HMIC clock because MVIP is not enabled. |
3 |
|
-3090 |
HMICERR_INVALID_MAP |
Not used. |
3 |
|
-3091 |
HMICERR_LOCAL_NOT_ENABLED |
Local is not enabled. Informational message. |
3 |
|
-3092 |
HMICERR_HW_INTERFACE_FAIL |
Unknown mode (not framed connect or connect). |
3 |
|
-3093 |
HMICERR_CONSUME_MESSAGE |
Not used. |
3 |
|
-3110 |
HMICERR_NO_RESOURCE |
No free entries in HMIC mapping database. |
3 |
|
-3111 |
HMICERR_INVALID_CLK_MAIN_SRC |
Invalid clock source. |
3 |
|
-3112 |
HMICERR_INVALID_CLK_FBK_SRC |
Invalid fallback source. |
3 |
|
-3113 |
HMICERR_INVALID_CLK_NTREF1_SRC |
Invalid NETREF1 source. |
3 |
|
-3114 |
HMICERR_INVALID_CLK_NTREF2_SRC |
Invalid NETREF2 source. |
3 |
|
-3115 |
HMICERR_INVALID_CLK_MAIN_PATH |
Invalid main clock path selection. |
3 |
|
-3116 |
HMICERR_INVALID_CLK_FBK_PATH |
Invalid fallback clock path selection. |
3 |
|
-3117 |
HMICERR_INVALID_HMIC_REFERENCE |
Invalid HMIC number. |
3 |
|
-3118 |
HMICERR_CLOCK_UPDATE_BUSY |
Unable to lock HMIC data. |
3 |
|
-3119 |
HMICERR_UNKNOWN_H100_MASTER |
Invalid selection for master mode. |
3 |
|
-3120 |
HMICERR_UNKNOWN_FBK_MODE |
Invalid selection for fallback mode. |
3 |
|
-3121 |
HMICERR_UNKNOWN_LSCX_OUTPUT |
Invalid LSCX stream. |
3 |
|
-3122 |
HMICERR_UNKNOWN_LSCX_CHOICE |
Invalid LSCX signal. |
3 |
|
-3123 |
HMICERR_UNKNOWN_FG_PIN_CFG |
Invalid frame group configuration. |
3 |
|
-3124 |
HMICERR_UNKNOWN_FG_SPEED |
Invalid frame group speed. |
3 |
|
-3125 |
HMICERR_UNKNOWN_FG_WIDTH |
Invalid frame group width. |
3 |
|
-3126 |
HMICERR_UNRECOGNIZED_REG |
Invalid register. |
3 |