Sample PPX configuration file

The following PPX configuration file contains sample switch definitions for a variety of NMS boards:

#                       ppx.cfg
#
#          --- Point-to-Point Switching Service ---
#          ---        Configuration             ---
#
#   This file defines to the point-to-point switching service
#   the available bus, timeslots, and switches it may use for
#   establishing connection paths.
#
#   This configuration file contains example switch definitions
#   for various NMS boards. Use this as a guide for
#   configuring the PPX service to your particular hardware
#   configuration.
#
#   Some Reminders:
#       - All switch numbers must be unique.
#       - The "DeviceNumber" is the logical board number established
#         with OAM board configuration.
#       - The PPX service speaks MVIP-95, not MVIP-90.
#
#

[PPX]
Fabric
        IdleCode = MU_LAW     # Default idle pattern [ MU_LAW | A_LAW ]

        Bus H100                        # H100 bus
            CTBUS:0..15:0..31           # 2 mbps Clocking
            CTBUS:16..23:0..63          # 4 mbps "
            CTBUS:24..31:0..127         # 8 mbps "
        End Bus

         Switch 0                       # CG 6000
             SwitchType = HMIC
             DeviceName = "agsw"
             DeviceNumber = 0
             Bus H100 ()
             Inputs
                 LOCAL:0..14(2):0..23   # Trunk (0..29 for E1)
                 LOCAL:16..18(2):0..127 # DSP
             End Inputs

             Outputs
                 LOCAL:1..15(2):0..23   # Trunk (0..29 for E1)
                 LOCAL:17..19(2):0..127 # DSP
             End Outputs
        End Switch

#        Switch 1                       # CG 6100
#            SwitchType = HMIC
#            DeviceName = "agsw"
#            DeviceNumber = 1
#            Bus H100 ()
#            Inputs
#                LOCAL:0..62(2):0..29   # Trunk (0..23 for T1)
#                LOCAL:64..66(2):0..479 # DSP
#            End Inputs
#            Outputs
#                LOCAL:1..63(2):0..29   # Trunk (0..23 for T1)
#                LOCAL:65..67(2):0..479 # DSP
#            End Outputs
#        End Switch

#        Switch 2                        # AG 4040
#            SwitchType = HMIC
#            DeviceName = "agsw"
#            DeviceNumber = 2
#            Bus H100 ()
#            Inputs
#                LOCAL:0..6(2):0..23     # Trunk
#                LOCAL:16..18(2):0..127  # DSP
#            End Inputs
#            Outputs
#                LOCAL:1..7(2):0..23     # Trunk
#                LOCAL:17..19(2):0..127  # DSP
#            End Outputs
#        End Switch

#       Switch 3                         # AG 4040C
#            SwitchType = HMIC
#            DeviceName = "agsw"
#            DeviceNumber = 3
#            Bus H100 ()
#            Inputs
#                LOCAL:0..14(2):0..23    # Trunk (E1: 0..29)
#            End Inuputs
#            Outputs
#                LOCAL:1..15(2):0..23    # Trunk (E1: 0..29)
#            End Outputs
#        End Switch

#        Switch 4                        # AG 2000
#            SwitchType = HMIC
#             DeviceName = "agsw"
#             DeviceNumber = 4
#             Bus H100 ()
#             Inputs
#                 LOCAL:0..2(2):0..7     # Trunk
#                 LOCAL:4..6(2):0..7     # DSP
#             End Inputs
#             Outputs
#                 LOCAL:1..3(2):0..7     # Trunk
#                 LOCAL:5..7(2):0..7     # DSP
#             End Outputs
#         End Switch

#        Switch 5                        # AG 2000C
#            SwitchType = HMIC
#             DeviceName = "agsw"
#             DeviceNumber = 5
#             Bus H100 ()
#             Inputs
#                 LOCAL:0..2(2):0..23    # Trunk
#                 LOCAL:4..6(2):0..23    # DSP
#             End Inputs
#             Outputs
#                 LOCAL:1..3(2):0..23    # Trunk
#                 LOCAL:5..7(2):0..23    # DSP
#             End Outputs
#         End Switch

#        Switch 6                        # QX 2000/100-4L
#            SwitchType = HMIC
#             DeviceName = "qxsw"
#             DeviceNumber = 6
#             Bus H100 ()
#             Inputs
#                 LOCAL:0..6(2):0..3     # line interfaces & DSP resources
#                 LOCAL:8..10(2):0       # local phone data and signal
#                 LOCAL:12:0             # audio
#             End Inputs
#             Outputs
#                 LOCAL:1..7(2):0..3     # line interfaces & DSP resources
#                 LOCAL:9..11(2):0       # local phone data and signal
#                 LOCAL:13:0             # audio
#             End Outputs
#         End Switch

#        Switch 7                        # CX 2000C
#            SwitchType = HMIC
#             DeviceName = "cxsw"
#             DeviceNumber = 7
#             Bus H100 ()
#             Inputs
#                 LOCAL:0..2(2):0..47    # 48 station interfaces
#                 LOCAL:4..6(2):0..47    # :0..31 for CX2000C-32
#             End Inputs                 # :0..15 for CX2000C-16
#             Outputs
#                 LOCAL:1..3(2):0..47    # 48 station interfaces
#                 LOCAL:5..7(2):0..47    # :0..31 for CX2000C-32
#             End Outputs                # :0..15 for CX2000C-16
#         End Switch

#        Connect
#            0:local:0:0 to 0:local:17:0 QUAD
#            0:local:0:2 to 0:local:17:2 QUAD NAILED
#        End Connect

End Fabric