Number of errored seconds.
Gauge
Read-only
p.7.1.2.n, where n = the index number of the DS1 interface.
For ESF and E1-CRC links, an errored second is a second with one or more path code violations, one or more out-of-frame defects, one or more controlled slip events, or a detected AIS defect.
For D4 and E1-noCRC links, the presence of bipolar violations also triggers an errored second.
This value is not incremented during an unavailable second.