snmpTrunkLog

Shows the status of digital trunks of each board in a chassis.

Usage

snmpTrunkLog address options

where:

Parameter

Description

address

Address or DNS name of a local or remote host running the SNMP agent about which to return information.

Valid options include:

Option

Description

-ccommunity_name

Specify a community name. The default is public.

-rn

Number of retries. The default is 1 retry.

-tn

Timeout in hundredths of a second. The default is 100 (1 second).

snmpTrunkLog is similar to the trunkmon utility. See the NMS OAM System User's Manual for information.

Procedure

Complete the following steps to run snmpTrunkLog:

Step

Action

1

From the command line, navigate to the \nms\ctaccess\demos\snmp\snmptrunklog directory (or the /opt/nms/ctaccess/demos/snmp/snmptruklog directory under UNIX).

2

Enter the following command:

snmpTrunkLog <address>

where address is the IP address for the machine.

The following example shows how to run snmpTrunkLog:

> snmpTrunkLog
SNMP Demonstration and Test Program  V.3.0 Nov 15 1999
NMS Communications Corporation.

Usage:
snmpChassScan [Address | DNSName] [options]
Address:  default is 127.0.0.1
options: -cCommunity_name, specify community default is 'public'
         -rN , retries default is N = 1 retry
         -tN , timeout in hundredths-seconds default is N = 100 = 1 second

h  Help     S  Sys info    L  Trunk list    Q  Quit

SEND A REQUEST FOR SYSTEM INFO TO: 10.1.20.45
System information:
System:        Hardware: x86 Family 6 Model 3 Stepping 4 AT/AT COMPATIBLE  - Software: Windows 2000
SysUpTime:     1:59:37.45
SysContact:    Joe Kilroy
Computer name: KILROY
Location:      NMS

SEND A REQUEST FOR TRUNKS TO: 10.1.20.45

Interface:2 Board:1 (AG_4040_1TE)  Trunk:0 Status: Loss of frame, NoSgnl
Interface:3 Board:1 (AG_4040_1TE)  Trunk:1 Status: Loss of frame, NoSgnl
Interface:4 Board:1 (AG_4040_1TE)  Trunk:2 Status: Loss of frame, NoSgnl
Interface:5 Board:1 (AG_4040_1TE)  Trunk:3 Status: Loss of frame, NoSgnl
Interface:6 Board:2 (AG_4040_2TE)  Trunk:0 Status: In service
Interface:7 Board:2 (AG_4040_2TE)  Trunk:1 Status: Loss of frame, NoSgnl
Interface:8 Board:2 (AG_4040_2TE)  Trunk:2 Status: In service
Interface:9 Board:2 (AG_4040_2TE)  Trunk:3 Status: Loss of frame, NoSgnl