The following table describes the hardware differences between AG 4040C and CG 6060C boards:
|
Item |
AG 4040C board |
CG 6060C board |
|
Board status LEDs |
No board status LEDs. |
Red, yellow, and green board status LEDs. |
|
Bus support |
Supports 32-bit, 33 MHz CompactPCI bus. |
Supports 32-bit, 33 MHz or 66 MHz CompactPCI bus. |
|
CAS signaling |
Processed in a DSP. |
Processed in the framer. |
|
Connections |
Limited to 256 simple connections on the H.110 bus. |
Can simultaneously connect (simplex) to all 4096 timeslots on the H.110 bus. |
|
CT bus timeslot connections |
A connection to or from a CT bus timeslot will fail if the timeslot is already connected in the other direction. |
If a connection is made to or from a CT bus timeslot, any existing connection in the other direction on that timeslot is disconnected. |
|
DSP connections |
Each DSP core has its own 64-slot TSI stream. |
Four DSP cores per TSI stream. Each local TSI stream has 128 timeslots. |
|
DSPs |
|
|
|
E1 impedance |
Default is 120 ohms but switch selectable to 75 ohm. |
Software configurable to 75 ohm, 100 ohm, 120 ohm, or high impedance. |
|
Echo cancellation |
Software echo cancellation. |
Proprietary echo cancellation chip. Software echo cancellation is also available. |
|
Ethernet |
No Ethernet connectivity. |
Dual 10/100Base-T Ethernet with LED speed and activity indicators on the front panel. |
|
Hot swap |
Hot swap monitor (hsmon) displays messages based on whether the board handles are flipped or if the board is physically extracted. |
Hot swap monitor (hsmon) does not differentiate between physical extraction of the board and the board handles being flipped when it displays messages. For more information, refer to the Dialogic® NaturalAccess™ OAM System Developer’s Manual. |
|
Signaling |
Signaling is switchable from trunk-to-trunk and between trunks and the CT bus. |
Does not support switching signaling from trunk-to-trunk or between trunks and the bus, only between trunks and DSPs. |
|
Dual Agere T8100A. |
Proprietary TSI. |
|
|
Up to 4 RJ-48C trunk interface jacks. |
Varies based on the board variant. Up to 8 RJ-48C interfaces or up to 2 Dialogic® MD1 RJ-21 interfaces. |
|
|
Red, yellow, and green LED per trunk. |
Green status LED per trunk. |