Specifies the type of cable connecting a CG 6060C board to the network.
NetworkInterface.T1E1[x].Impedance = cable_type
x = 0-(n-1) (0-based trunk number or range of trunk numbers where n equals the number of trunks on the board.)
Read/Write
String
G703_120_OHM
DSX1 | G703_75_OHM | G703_120_OHM | HIGH_IMPEDANCE
NetworkInterface.T1E1[0..7].Impedance = G703_120_OHM
The NetworkInterface.T1E1[x].Impedance setting varies based on the CG 6060C board variant and the network connection. Valid settings are:
|
Setting |
Description |
|
DSX1 (T1 only) |
For DSX1 cables (up to 655 feet - short haul). |
|
G703_75_OHM (E1 only) |
For G.703-standard 75 ohm cables. |
|
G703_120_OHM (E1 only) |
For G.703-standard 120 ohm cables. |
|
HIGH_IMPEDANCE (T1 or E1) |
Reserved for T1 or E1 trunk monitoring applications. |
For more information, refer to Configuring the T1 or E1 interface.
NetworkInterface.T1E1[x].CRCMFMode, NetworkInterface.T1E1[x].D_Channel, NetworkInterface.T1E1[x].FrameType, NetworkInterface.T1E1[x].Length, NetworkInterface.T1E1[x].LineCode, NetworkInterface.T1E1[x].SignalingType, NetworkInterface.T1E1[x].Type