Clocking.HBus.ClockSource

Specifies the clock reference origin.

For information about setting up CT bus clocking, and rules and restrictions for configuring CT bus clocking, refer to Configuring board clocking.

Syntax

Clocking.HBus.ClockSource = clock_source

Access

Read/Write

Type

String

Default

OSC

Allowed values

OSC | A_CLOCK | B_CLOCK | NETWORK | NETREF

Example

Clocking.HBus.ClockSource = OSC

Details

Valid entries for the keyword include:

Value

Description

OSC

Uses the on-board oscillator as a reference.

A_CLOCK

Causes the board to act as a clock slave to the H.100 bus A clock by deriving the local clock from the bus.

Another H.100 board (or H.110 board) must drive the clock on the bus.

B_CLOCK

Causes the board to act as a clock slave to the H.100 bus B clock by deriving the local clock from the bus.

Another H.100 board (or H.110 board) must drive the clock on the bus.

NETWORK

Causes the board to derive the local clock, telephony bus clock, and line transmit clock using the clock extracted from one of the BRI trunks.

NETREF

H.100 network reference.