NetworkInterface.T1E1[x].Impedance

Specifies the type of cable connecting a CG 6565E board to the T1 or E1 network.

Syntax

NetworkInterface.T1E1[x].Impedance = cable_type

x = 0-(n-1) (0-based trunk number or range of trunk numbers where n equals the number of trunks on the board.)

Access

Read/Write

Type

String

Default

G703_120_OHM

Allowed values

DSX1 | G703_75_OHM | G703_120_OHM | HIGH_IMPEDANCE

Valid settings are:

Note: To use E1 75 ohm impedance on the CG 6565E board variant with an MD1 Mini RJ-21 interface, you must use a balun to convert the impedance from 120 ohm to 75 ohm.

Example

NetworkInterface.T1E1[0..7].Impedance = G703_120_OHM

Details

Trunk impedance on the CG 6565E is controlled through a board configuration file. Because trunks are configured in pairs, the configuration setting must be identical for both trunks in a given pair.

The following table lists the trunk pairings for the CG 6565E daughterboards:

Daughterboard

T1/E1 interface

Trunk pairings

Supported settings

One- or two-trunks

MD1 RJ-45 (wired as an RJ-45)

0 or 0 and 2

DSX1

G703_75_OHM

G703_120_OHM

HIGH_IMPEDANCE

Four-trunks

MD1 RJ-45

0 and 2

1 and 3

DSX1

G703_75_OHM

G703_120_OHM

HIGH_IMPEDANCE

Eight-trunks

MD1 Mini RJ-21

0 and 1

2 and 3

4 and 5

6 and 7

DSX1

G703_75_OHM (use an external balun)

G703_120_OHM

HIGH_IMPEDANCE

Note: For 75 ohm, you must use a balun to convert the impedance from 120 ohm to 75 ohm. For more information, refer to Cabling a CG 6565E board.

For more information, refer to Configuring the T1 or E1 interface.

See also

NetworkInterface.T1E1[x].CRCMFMode, NetworkInterface.T1E1[x].D_Channel, NetworkInterface.T1E1[x].FrameType, NetworkInterface.T1E1[x].Length, NetworkInterface.T1E1[x].LineCode, NetworkInterface.T1E1[x].SignalingType, NetworkInterface.T1E1[x].Type