Specifies the type of cable connecting a CG 6565E board to the T1 or E1 network.
NetworkInterface.T1E1[x].Impedance = cable_type
x = 0-(n-1) (0-based trunk number or range of trunk numbers where n equals the number of trunks on the board.)
Read/Write
String
G703_120_OHM
DSX1 | G703_75_OHM | G703_120_OHM | HIGH_IMPEDANCE
Valid settings are:
DSX1 for T1
G703_75_OHM for E1 75 ohm (MD1 RJ-45 variants only)
G703_120_OHM for E1 120 ohm
HIGH_IMPEDANCE for T1 or E1
Note: To use E1 75 ohm impedance on the CG 6565E board variant with an MD1 Mini RJ-21 interface, you must use a balun to convert the impedance from 120 ohm to 75 ohm.
NetworkInterface.T1E1[0..7].Impedance = G703_120_OHM
Trunk impedance on the CG 6565E is controlled through a board configuration file. Because trunks are configured in pairs, the configuration setting must be identical for both trunks in a given pair.
The following table lists the trunk pairings for the CG 6565E daughterboards:
Daughterboard |
T1/E1 interface |
Trunk pairings |
Supported settings |
One- or two-trunks |
MD1 RJ-45 (wired as an RJ-45) |
0 or 0 and 2 |
DSX1 G703_75_OHM G703_120_OHM HIGH_IMPEDANCE |
Four-trunks |
MD1 RJ-45 |
0 and 2 1 and 3 |
DSX1 G703_75_OHM G703_120_OHM HIGH_IMPEDANCE |
Eight-trunks |
MD1 Mini RJ-21 |
0 and 1 2 and 3 4 and 5 6 and 7 |
DSX1 G703_75_OHM (use an external balun) G703_120_OHM HIGH_IMPEDANCE Note: For 75 ohm, you must use a balun to convert the impedance from 120 ohm to 75 ohm. For more information, refer to Cabling a CG 6565E board. |
For more information, refer to Configuring the T1 or E1 interface.
NetworkInterface.T1E1[x].CRCMFMode, NetworkInterface.T1E1[x].D_Channel, NetworkInterface.T1E1[x].FrameType, NetworkInterface.T1E1[x].Length, NetworkInterface.T1E1[x].LineCode, NetworkInterface.T1E1[x].SignalingType, NetworkInterface.T1E1[x].Type