Activates or deactivates the special AG 2000-BRI clock fallback mechanism.
For information about setting up CT bus clocking, and rules and restrictions for configuring CT bus clocking, refer to Configuring board clocking.
Clocking.HBus.BriRef = setting
Read/Write
String
NO
YES | NO
If enabled, when the clock master's references both fail, the AG plug-in selects another board to provide a timing reference for the clock master. The signal is passed to the clock master using NETREF.